Back

Candidate for your review

Transmission and distribution / T&D- UK electricity / Electricity: UK / kWh / kWh

Check the activity basis, boundary and source before using this factor.

Activity location
Source-specific (see conditions)
Reference period
2026
Activity basis
T&D- UK electricity / Electricity: UK / kWh; 1 kWh
Emissions boundary
Scope 3 / Transmission and distribution
Reference unit
kg CO2e / kWh
Revision
uk2026-uk-7b2281751e2a35ff15446167-r1

When to use this factor

  • 원문 활동·단위 / Source activity and unit: Scope 3 / Transmission and distribution / T&D- UK electricity / Electricity: UK / kWh / kWh (Factors by Category!A3627:J3630)
  • 적용 조건 / Condition: 전력망 손실과 지역난방·증기 배분 손실을 활동 유형별로 구분함. 구매·사용한 kWh에 해당 단계 계수를 적용하는 원문 구조임. (Transmission and distribution!A8,A11,A12,A13,A18,A19,A33; Heat and steam!A13; Methodology PDF pp. 29,42)
  • 적용 조건 / Condition: 전력 생산 단계 및 WTT 단계와 다른 항목이며 수치 합산 여부를 서비스가 결정하지 않음. (Transmission and distribution!A8,A11,A12,A13,A18,A19,A33; Heat and steam!A13; Methodology PDF pp. 29,42)
  • 원문 예외 / Source exception: 같은 섹션의 전력 손실과 열 배분 손실은 서로 대체할 수 없음. (Transmission and distribution!A8,A11,A12,A13,A18,A19,A33; Heat and steam!A13; Methodology PDF pp. 29,42)
  • 원문 예외 / Source exception: 지역난방은 원문 방법론이 5% 손실 가정을 설명함. 실제 설비의 실측 손실률을 의미하지 않음. (Transmission and distribution!A8,A11,A12,A13,A18,A19,A33; Heat and steam!A13; Methodology PDF pp. 29,42)
  • 원문 예외 / Source exception: 해외 전력 T&D는 이 원문 제공 범위에서 제외됨. (Transmission and distribution!A8,A11,A12,A13,A18,A19,A33; Heat and steam!A13; Methodology PDF pp. 29,42)
  • 사용 시 확인 / Verify before use: Not confirmed: 열·증기 실제 네트워크 손실과 국가별 적합성은 별도 확인 대상임. (Transmission and distribution!A8,A11,A12,A13,A18,A19,A33; Heat and steam!A13; Methodology PDF pp. 29,42)
  • 송배전 손실만: 구매·사용한 전력 kWh에 대응하는 그리드 송배전 손실의 Scope3 계수임. 발전 배출 또는 전력 소비 총량과 구분함. 이미 손실을 포함한 합산 계수에 중복해서 더하지 않음. (Transmission and distribution!A8,A18,A19,A21:H22; Methodology PDF p29 Stage5 paragraph 1.3)
  • 총량의 의미 / CO2e total: 원문 CO2e 총량을 그대로 표시함. 가스별 CO2e 기여분을 다시 더하거나 GWP를 다시 곱하지 않음. 사용자가 활동·지역·연도·경계 적합성을 선택해야 함. (Factors by Category!J3627)
MetricValueReference unitActivity basis
CO2e1.299E-2kg CO2e / kWh1 T&D- UK electricity / Electricity: UK / kWh; 1 kWh

Original source

DESNZ · UK Government GHG Conversion Factors 2026

Factors by Category!A3627:J3630; Transmission and distribution!A8,A11,A12,A13,A18,A19,A33; Heat and steam!A13; Methodology PDF pp. 29,42

Source notes

  • Contains public sector information licensed under the Open Government Licence v3.0.
  • Licence: https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/
  • Source: DESNZ 2026 conversion factors, revised July 2026 flat file Version 1.2; full set Version 1 and 2026 methodology. No government endorsement is implied.
  • Numeric source total and unit are preserved without conversion. Reporting year 2026 is not necessarily the observation year of underlying source data.
  • Source category, activity dimensions and section-specific exceptions apply. Catalog publication does not select a factor for a user calculation.

Copy reference

https://factorfind.win/en/factors/uk2026-uk-7b2281751e2a35ff15446167-r1

uk2026-uk-7b2281751e2a35ff15446167-r1 · 2026 · DESNZ · UK Government GHG Conversion Factors 2026